Gambar Titan 42U-120-30HV 120KVA

UPS PROLINK Titan Series (3P/3P)-Tower

ProlInk Titan Series is modular three-phase input / three-phase output online double conversion UPS takes scalability to a whole new level. Based on
a scalable design, the Titan comes with a wide range of capacity, ranging from as low as 20kVA to as high as 300kVA. The Titan series is designed with
a N+X parallel redundancy system that allows two or more UPS modules to operate in parallel and as back-up for each other.
This unit provides an ideal protection for data centres, telecommunication facilities and other critical applications. Up to ten 30kVA modules can be
fitted into a standard cabinet to simplify maintenance and replacement activities. The Series guarantees a low mean-time-to-repair (MTTR), giving
users a shorter elapsed time between the point of repair and the point of equipment recovery. Some distinct features of the PROLINK Titan series are
as listed below

– HIGH EFFICIENCY ONLINE DOUBLE CONVERSION TECHNOLOGY
– HIGH SCALABILITY
– UNITY OUTPUT POWER FACTOR
– MODULAR DESIGN LOWERS MTTR
– N+1 AND N+X PARALLEL REDUNDANCY FOR POWER GUARANTEE
– EASE OF INSTALLATION AND MAINTENANCE

Key Features Titan 42U-120-30HV 120KVA

High Efficiency Online Double Conversion Technology
PROLINK Titan series is designed with the latest online
double conversion technology that provides a high efficiency
rating of 94.5% at 50% load. With such a high efficiency
rating, the Titan can save hundreds of dollars each year.

High Scalability
Based on a scalable design, the Titan Series simplifies future
expansion by making UPS units easily upgradable. This architecture allows you to meet power demands by adding
additional modules vertically in a single rack enclosure.

Unity Output Power Factor
With a unity output factor (kVA = kW), the PROLINK Titan UPS
system is 100% compatible with today’s high power factor
loads. It is able to meet the latest server requirements, giving
the best value for your IT investments.

Modular Design Lowers MTTR
The modular design ensures uninterrupted power supply
during UPS maintaining and replacing activities. Also, the
Titan Series guarantees a low mean-time-to-repair (MTTR),
giving users a shorter elapsed time between the point of
repair and the point of equipment recovery.

N+1 and N+X Parallel Redundancy for power guarantee
PROLINK Titan series is designed with scalable architecture
which allows user to optimise cost expense to meet power
demands by vertically expanding in a single rack enclosure from
30KVA to 300KVA and achieve N+1 or N+X redundancy in the
same rack.

Ease Of Installation and Maintenance
With a built-in maintenance bypass feature, the UPS is able to
deliver continuous power to the critical load during maintenance. Better yet, the Titan comes with a front access concept
to facilitate installation.

Flexible Battery configuration adapts different applications
Battery numbers can be adjusted flexibly. It will adapt different
power demands and shorten system downtime. Battery
voltage can be set from 32 to 40 pieces per string.

Highly reliable operation with redundant power supply in STS
PROLINK Titan series provides 2 power supplies in STS,
ensuring no risks of shut down.

User adjustable charging current
PROLINK Titan series provides maximum 8A or 6A charging
current for every power module and its user adjustable
requirement.

High Overload Capability
PROLINK Titan series supports 110 % overload for 60 mins,
125% for 10 mins and 150% for 1 min.

Graphic 5.7” LCD for easy management
For easy management, the intuitive design of 5.7” graphic LCD
display enhances the readability of identified and advanced
configuration. Optional 10” touch LCD panel is available for the
system.

SPECIFICATIONS Titan 42U-120-30HV 120KVA

GENERAL
– UPS Type : Tower
– Phase : 3 phase in / 3 phase out
– Cabinet Capacity* : 120KW
– One Power Module Capacity : 30KVA / 30KW
– Max. Power Module Capacity : 4
– Max. Battery Set No.** : 5
– Dimension (mm) : 1100 x 600 x 2010 (D x W x H)
– Weight (kgs) : 932

INPUT
– Connection Type : Terminal
– Nominal Voltage : 3 x 380VAC / 400VAC / 415VAC (3Ph+N)
– Voltage Range : 305 ~ 478 VAC at 100% load 208 ~ 304VAC at <70% load
– Frequency Range : 40Hz ~70Hz
– Power Factor : > 0.99 at 100% load >0.98 at 50% load
– THDi : < 3% @ 100% load

OUTPUT
– Connection Type : Terminal
– Nominal Voltage : 3 x 380VAC / 400VAC / 415VAC (3Ph+N)
– Voltage Regulation (Steady state) : ≦ ± 1% Typical (balanced load) ≦ ± 2% Typical (unbalanced load)
– Frequency Range (Synchronized) : 46~54Hz or 56~64Hz
– Overload Capability : 1 hour for 110% 10 mins for 125% 1 min for 150% and 200ms for >150%
– Efficiency : Up to 94.5%
– Harmonic Distortion : ≦ 2% THD (Linear Load) ≦ 4% THD (Non-linear Load)

CONNECTIVITY, CONTROL & MONITORING
– Front panel: Status LED, Function keys, LCD display
– Communication : Smart RS232* USB Port Emergency Power Off (EPO)

BATTERY
– TYPE : Built-in Battery
– Nominal Voltage : +/- 216V (12V x 36 Pcs)
– Maximum Voltage : +/- 240V (12V x 40 Pcs)
– Minimum Voltage : +/- 192V (12V x 32 Pcs)
– Maximum Charging Current (Per Power Module) : 8A

 